Basic Info.
Application
School, Hospital, Lab
Resistivity
18.2megohm-Cm@25′c
Heavy Metal Ion(Ppb)
<0.1ppb
Total Organic Carbon(Toc)
<10ppb
Dimension
Lxwxh:50X36X54cm/ About22kg
Electric Requirements
AC110-220V,50-60Hz/120W
Transport Package
Packed by Standard Exporting Carton
Specification
Certified by CE, ISO9001: 2008 and SGS
Product Description
1)Application
Medical equipment produce ultra pure water suitable for GC, HPLC, IC, ICP, PCR application and nanlysis, Meteorological analysis, analysis reagent and drug configuration, Dilution, precision instrument analysis, amino acid analysis, etc
2)Flow schematic PF+KDF+AC+RO+AC+DI+TF
LV. 1 10' spun fiber filter
LV. 2 10' mixed KDF filter
LV. 3 10' active carbon filter
LV. 4 100GPD RO membrane
LV. 5 Post active carbon filter
LV. 6 Ultra pure polishing resin cartridge
LV. 7 (0.45+0.1)μ M importing PES terminal filter
3)Performance characteristics
Automatic micro-computer system, multi-menu operating,
Super-large LCD display, the resolution is 240*128, animation mode display.
3 road on-line water monitoring, monitor the inlet water, RO water and ultra pure water quality
It could disinfect all the pipes with tablet
Flush the RO membrane automatically, prolong RO membrane serive life
Detect fault automatically, provide security guarantees
The system recirculates water when the system is not in use in order to maintain water quality
The system setting are protected by the password, prevent unauthorized change
Can set pretreament, RO membrane, UV lights and ultra purified column life, show the with and remaining life of consumables
Set timing and fixed quality function(Timing: 1-99min; Fixed quality: 0.1-18.2 MΩ -cm)
You could choose the LCD display work or not
Various specifications storage tanks can be selected to meet diffierent needs
Integration plastic molding chassis, human body engineering design, accor with GLP standard
The KDF filter has longer service life, operation cost reduction.
The U. S. DOW DOW or fluid FCS produced, realized the the combination of RO membrane long life with high quality water.
The original import nuclear level resin, guarantee top water quality
0.45+0.1µ M import PES polyether sulphone composite membrane filter terminal aseptic filter, assuring water quality aseptic
4)After-sales service
· The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:
(1). Damage caused by maloperation or use in abnormal situations.
(2). Disassembly any part of the machine or human-behavior damage.
(3). Not repaired by our serviceman.
5)Main Market
Asia, The Middle East, Eastern Europe and South Africa
Model | Standard | Eliminating endotoxin | Low TOC | Comprehensive |
Master-S15 | Master-S15 UF | Master-S15 UV | Master-S15 UVF |
Master-S30 | Master-S30 UF | Master-S30 UV | Master-S30UVF |
Flow procedure | PF+KDF+AC+RO+AC+DI+TF | PF+KDF+AC+RO+AC+DI+UF+TF | PF+KDF+AC+RO+UV+AC+DI+TF | PF+KDF+AC+RO+UV+AC+DI+UF+TF |
Application | GC,HPLC,IC,ICP PCR, weather analysis Amino acid analysis Reagent preparation | Molecular biology Cell and tissue cultivation Life science, IVF electrophoresis | HPLC,IC,ICP-MS TOC and organism analysis CF-AAS, toxicology study Environmental analysis | HPLC,IC,ICP-MS,CF-AAS, Physics, electrochemistry, Molecular biology, Cell cultivation |
Ultrapure water quality | Resistivity | 18.2MΩ.cm@25ºC |
Heavy metal ions | < 0.1ppb |
TOC | <10 ppb | <3 ppb |
Bacteria | <0.1CFU/ml |
Endotoxin | - | <0.001EU/ml | - | <0.001EU/ml |
Particle(>0.22μm) | <1/ml |
RO water quality | < TDS(ppm, mg/l) of tap water×5% |
Technical specification | Output(25ºC ) | 15 Liters/hour* (plus model:30 Liters/hour*) |
Flow rate | 2 liters/min(with pressure tank) |
Pure water outlet | RO water, ultrapure water |
Dimension/Weight | Length×Width×Height:50×36×54cm / 20-30Kg |
Electric requirements | AC110-220V,50/60Hz,120W |
Control system | Mode display | Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing remind |
Safety | low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection |
System monitor | Monitoring quality of feed water, RO water and ultrapure water, temperature, used and left time of consumables |
Feed water requirement | Tap water, inlet TDS<200 ppm,5-45ºC, 1.0-4.0 kgf/cm 2 (if inlet TDS>200ppm, extra pretreatment is recommended) |
Purification system | Pretreatment unit | 5μm spun fiber filter×1+Kinetic degradation fluxion filter×1+Granular active carbon filter×1 |
RO unit | 100 GPD RO membrane×1 ( Plus model:100 GPD RO membrane×2) |
Subsequent unit | Post active carbon filter×1+Ultrapure polishing resin cartridge× 4+(0.45+0.1) μm terminal filter×1 UV model:+Double wavelength(185&254)nm UV lamp cartridge×1 UF model:+5000 Doulton UF cartridge×1 UVFmodel:+Double wavelength(185&254)nm UV lamp cartridge×1+5000 Doulton UF cartridge×1 |
Standard configuration | Main body(including:1 set cartridge)+4 gallon tank + accessory box |
Address:
Building 113, Lane 255, South Sizhuan Road, Songjiang District, Shanghai, China
Business Type:
Manufacturer/Factory
Business Range:
Agriculture & Food, Instruments & Meters, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001
Company Introduction:
Hitech Instruments Co., Ltd, established in 2003, specializes in manufacturing laboratory water purification systems and related apparatus. Except for the small capacity lab water purification systems, we also provide the service of large or medium-sized water treatment engineering design, complete supply, installation debugging, technical reform and technical training etc. In addition, we can provide the professional training of the lab water knowledge, and optimize the existing water purification system to help customers to reduce the cost and guarantee the stable pure water supply.
With tap water inlet, integrating various advanced water purification technologies and process control methods, our water purification systems can completely meet, even exceed, the pure water standard of ASTM, NCCLS Class I etc. It can meet the meet of advanced lab water use for different purpose. It can be widely used in the field of chemistry, biology, pharmacy, medicine, micro-electronics, semiconductor etc, meeting the application requirements of spectral analysis, chromatographic analysis, cell culture, protein purification and molecular biology.
We will constantly bring in new technology, and devote ourselves to the development of new products in order to cover diversified demands from clients. We will provide comprehensive solutions for the lab pure water with professional pre-sales support and impeccable after-sales service.
We aim to integrate products with the world market, establish first-class brand by excellent quality and gain market shares by top brand.