1)Application
Ultra-pure water fill the system, experimental vessels flushing, water plant growing, microbiological
Media preparation, reagent configuration, buffer a configuration, ion chromatography
Photographic films with purified water washing, pharmaceutical and for stability experiment box,
Meteorological laboratory equipment, hydrogen generator, water etc.
2)Flow schematic PF+AC+RO+AC+DI+TF
LV. 1 20' spun fiber filter
LV. 2 20' granular active carbon filter
LV. 3 20' active carbon filter
LV. 4 100GPD RO membrane
LV. 5 10' accurate active carbon filter
LV. 6 12L mixed bed resin cartridge
LV. 7 0.2μ M import PES terminal filter
3)
1. Automatic microcomputer control system, multi-level menu operation
2 .Backlit LCD screen (resolution: 128 × 64, Size: 66 × 33mm), full real-time animated display mode
3. 2-way online sensor, detect the quality of RO water (conductivity), DI water (resistivity) respectively.
4. Self-flushing of the RO membrane (flushing every 2 hours), extended RO membrane life
5. The cartridges' life-span can be set, the time used and left can be displayed, replacing auto-reminding, avoiding the decline of water quality.
6. Multiple alarm functions: such as no water, full water, disqualification of feed water, RO water, DI deionized water or ultrapure water, cartridges' life-span ends.
7. Human engineering desingn, manual / automatic water dispense, and timing set (1-99min), water quality alarm function (if resistivity <16MΩ.cm)
8. System time setting function (year / month / day / hour / minute)
9. Level II password, protect all the parameters setting, and prohibit any unauthorized setting changes
10. Has indicate lamp of running, alarm, full water, all system conditions at a glance
11.Built-in 12 liters pressure water tank, saving laboratory space, installation and maintenance easier
12. Compatible two kinds of water storage tank, different external tanks(optional), to meet every need and assure ample water-supply
13. System circulates and sanitization system to maintain ultrapure water's quality when system is not in use. (optional)
14. External hidden DC24V power supply, it's lower than human security for easy maintenance replacement and ensure safety
15. Integrated molding plastic housing, ergonomic design, water and power independent structure
16. Pretreatment cartridges, RO module, ultrapure cartridges, all designed to modularization independently. Easy to maintenance and replacement.
17. Water pipes and fast-plug adaptor, assure high quality ultrapure water
18. KDF pretreating cartridge, replace the ordinary active carbon, prolong the life-span to 12 months, reduce the running cost
19. Dow's RO membrane, ensure stable operation and high desalinization rate
20. 4 in 1 mixed bed resin cartridge (also can be divided to 4 independent cartridge), with DOW's nuclear-grade polishing resin, ensure water's quality
21. 254nm wavelength ultraviolet lamp module, restrain bacteria's increase and reduce TOC. (UT series.)
22. (0.45+0.1)µm double layer PES terminal disinfection filter, assure the quality absolutely axenic. (Optional)
4)After-sales
The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:
(1). Damage caused by maloperation or use in abnormal situations.
(2). Disassembly any part of the machine or human-behavior damage.
(3). Not repaired by our serviceman.
5)Main Market
Asia, The Middle East, Eastern Europe and South Africa
Related link
HTTP: //www. High-tech. Cn/prodetail_en. Asp? ID=5&lii=4
5)Main Market
Asia, The Middle East, Eastern Europe and South Africa
http://high-tech1.en.made-in-china.com
Model | Standard | Eliminating endotoxin | Low TOC | Comprehensive |
Eco-S15 | Eco-S15 UF | Eco-S15 UV | Eco-S15 UVF |
Eco-S30 | Eco-S30 UF | Eco-S30 UV | Eco-S30 UVF |
Flow procedure | PF+KDF+AC+RO+AC+DI+TF | PF+KDF+AC+RO+AC+DI+UF+TF | PF+KDF+AC+RO+UV+AC+DI+TF | PF+KDF+AC+RO+UV+AC+DI+UF+TF |
Application | GC,HPLC,IC,ICP PCR, weather analysis Amino acid analysis Reagent preparation | Molecular biology Cell and tissue cultivation Life science, IVF electrophoresis | HPLC,IC,ICP-MS TOC and organism analysis CF-AAS, toxicology study Environmental analysis | HPLC,IC,ICP-MS,CF-AAS, Physics, electrochemistry, Molecular biology, Cell cultivation |
Ultrapure water quality | Resistivity | 18.2MΩ.cm@25ºC |
Heavy metal ions | < 0.1ppb |
TOC | <10 ppb | <3 ppb |
Bacteria | <0.1CFU/ml |
Endotoxin | - | <0.001EU/ml | - | <0.001EU/ml |
Particle(>0.22μm) | <1/ml |
RO water quality | < TDS(ppm, mg/l) of tap water×5% |
Technical specification | Output(25ºC ) | 15 Liters/hour* (plus model:30 Liters/hour*) |
Flow rate | 2 liters/min(with pressure tank) |
Pure water outlet | RO water, ultrapure water |
Dimension/Weight | Length×Width×Height:50×36×54cm / 20-30Kg |
Electric requirements | AC100-240V,50/60Hz,120W |
Control system | Mode display | Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing remind |
Safety | low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection |
System monitor | Monitoring quality of feed water, RO water and ultrapure water, temperature, used and left time of consumables |
Feed water requirement | Tap water, inlet TDS<200 ppm,5-45ºC, 1.0-4.0 kgf/cm 2 (if inlet TDS>200ppm, extra pretreatment is recommended) |
Purification system | Pretreatment unit | 5μm spun fiber filter×1+Kinetic degradation fluxion filter×1+Granular active carbon filter×1 |
RO unit | 100 GPD RO membrane×1 ( Plus model:100 GPD RO membrane×2) |
Subsequent unit | Post active carbon filter×1+Ultrapure polishing resin cartridge× 4+(0.45+0.1) μm terminal filter×1 UV model:+Double wavelength(185&254)nm UV lamp cartridge×1 UF model:+5000 Doulton UF cartridge×1 UVFmodel:+Double wavelength(185&254)nm UV lamp cartridge×1+5000 Doulton UF cartridge×1 |
Standard configuration | Main body(including:1 set cartridge)+3 gallon tank + accessory box |